Magnetic Flow Meter Application

Magnetic Flow Meter Application

Magnetic Flow Meter Application

JYLDE series magnetic flow meter application for the pipes with Diameter of various pipes.and It is suitable for chemical industry, electric power, metallurgy, petroleum, water supply,domestic water and drainage, paper making, medicine, food and other departments.
 

Advantage :

1. JYLDE electromagnetic flowmeter adopts high stability and high efficiency, and is designed with a wide input range of multiple sets of isolated power switches.

2. Easy to operate, JYLDE electromagnetic flowmeter is automatically set according to the range of 0~10m/s without changing the range.

3. With automatic operation function, the average flow is large, and it is easy to calibrate the flowmeter.

Application:

The JYLDE series of intelligent electromagnetic flowmeters are manufactured according to the law of electromagnetic induction. They are used to measure the volumetric flow of conductive liquids in pipelines, water, sewage, mud, mud, acid, alkali, salt and food slurry, and are widely used.

 

Types of magnetic flow meter

Magnetic Flow Meter Application

Parameter

Max flow rate

15m/s

Accuracy

±0.5% ,±0.2%

Fluid conductivity

>5μS/cm

Nominal pressure

0.6Mpa,1.0Mpa,1.6Mpa,4.0Mpa(customized for high

Caliber

DN6-DN3000

Liner material

PTFE,PFA,F46,Neoprene ,Polyurethane

Electrode

SUS316, Hastelloy B, Hastelloy C,

Titanium, Tantalum, Platinum-iridium

Ambient humidity

5-100%RH(Relative humidity)

Ambient temperature

-25℃ to +60℃

Measuring range

1500:1,flow rate <15m/s

Structure type

Integrate type,Remote type ,Insertion type ,ex-proof type

Protection level

IP65(standard ) ,IP68(Optional )

Ex-proof Mark

ATEX

Power supply

24V ,220V ,3.6V battery

Signal output

4-20Ma , pulse

Communication protocol

RS485(Modbus ),Hart

Product standard

JB/T9248-1999 electromagnetic flowmeter

Selection of lining material

Electrodes material

Corrosion resistance

SS316

Applicable to industrial/municipal drinking water, wastewater and low corrosive mediums.

Hastelloy B

It has good corrosion resistance to all concentrations of hydrochloric acid below the boiling point, and is also resistant to oxidizing acids, alkalis, and non-oxidizing salt solutions such as sulfuric acid, phosphoric acid, and organic acids.

Hastelloy C

It is resistant to oxidizing acids, such as nitric acid, mixed acids, and also resistant to oxidizing salts. If the hypochlorite solution is higher than normal temperature, seawater will corrode.

Titanium

It can withstand the corrosion of sea water, various chlorides and hypochlorites, oxidizing acids, organic acids, and alkalis, but is not resistant to the corrosion of relatively pure reducing acids. However, if the acid contains an oxidizing agent, the corrosion is greatly reduced.

Tantalum

It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid and alkali, it is resistant to corrosion by almost all chemical media

 

Flow Range

Flow rate—-flow comparison table

0.01

1

2

3

4

5

15

15

0.0064

0.6362

1.2723

1.9085

2.5447

3.1809

9.5426

20

0.0113

1.1310

2.2619

3.3929

4.5239

5.6549

16.9646

25

0.0177

1.7671

3.5343

5.3014

7.0686

8.8357

26.5072

40

0.0452

4.5239

9.0478

13.5717

18.0956

22.6195

67.8584

50

0.0707

7.0686

14.1372

21.2058

28.2743

35.3429

106.0288

65

0.1195

11.9459

23.8919

35.8377

47.7836

59.7295

179.1886

80

0.1810

18.0956

36.1911

54.2867

72.3823

90.4779

271.4336

100

0.2827

28.2743

56.5487

84.8230

113.0973

141.3717

424.1150

150

0.6362

63.6173

127.2345

190.8518

254.4690

318.0863

954.2588

200

1.1310

113.0973

226.1947

339.2920

452.3893

565.4846

1696.4600

300

2.5447

254.4690

508.9380

763.4070

1017.8760

1272.3450

3817.0351

350

3.4636

346.3606

692.7212

1039.0818

1385.4424

1731.8030

5195.4089

400

4.5239

452.3893

904.7787

1357.1680

1809.5574

2261.9467

6785.8401

450

5.7256

572.5553

1145.1105

1717.6658

2290.2210

2862.7763

8588.3289

500

7.0686

706.8583

1413.7167

2120.5750

2827.4334

3534.2917

10602.8752

600

10.1788

1017.8760

2035.7520

3053.6281

4071.5041

5089.3801

15268.1403

700

13.8544

1385.4424

2770.8847

4156.3271

5541.7694

6927.2118

20781.6354

800

18.0956

1809.5574

3619.1147

5428.6721

7238.2295

9047.7868

27143.3605

900

22.9022

2290.2210

4580.4421

6870.6631

9160.8842

11451.1050

34353.3157

1000

28.2743

2827.4334

5654.8668

8482.3002

11309.7336

14137.1669

42411.5008

1200

40.7150

4071.5041

8143.0082

12214.5122

16286.0163

20357.5204

61072.5612

1400

55.4177

5541.7694

11083.5389

16625.3083

22167.0778

27708.8472

83126.5416

1600

72.3823

7238.2295

14476.4589

21714.6884

28952.9179

36191.1474

108573.4421

1800

91.6088

9160.8842

18321.7684

27482.6525

36643.5367

45804.4209

137413.2627

2000

113.0973

11309.7336

22619.4671

33929.2007

45238.9342

56548.6678

169646.0033

FAQ

Q:How long will you give me the reply ?

A: We will reply you in 1 hours as soon as possible , with in 10 hours if at night .

Q:Do you offer OEM service ?

A:Yes ,Pleasure feel free to send us your requirements .

Q: What is the material of the electromagnetic flowmeter?

A: Carbon steel, 304 stainless steel, 316 stainless steel.

Q:How about warranty time of your products ?

A:2 years .

Why chose us

1. Our flowmeters have been exported to more than 40 countries, and we have established long-term and stable cooperative relations with more than 30 flowmeter buyers.

2. Two QC inspections before 100% shipment.

3. ISO, CE, SGS standards and high-quality products with highly competitive prices.

4. All instruments have been 100% approved by the National Bureau of Metrology.

Certification

Certification

 

Factory

 

factory

Magnetic Flow Meter Application

Magnetic Flow Meter Application factory

 

Register an Interest


Provide Your Information



ICTC ICTC