Wastewater Flow Meter
Wastewater Flow Meter
Features:
1): The converter of Wastewater Flow Meter adopts 16 high-performance microprocessors, 2x16LCD display, convenient parameter setting and reliable programming.
2): Explosion-proof instrument box is used in corresponding explosion-proof places.
3): The nominal diameter of the series is DN3-DN3000, and the sensor lining and electrode materials have a variety of choices.
4): The converter adopts a novel excitation method with a low power consumption, stable zero position, and high precision.
5); The converter can be integrated or separated with the sensor.
6): The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity.
7): JYLDE electromagnetic flowmeter is a two-way measurement system, with three calculators: positive total, reverse total difference;
8): The Wastewater Flow Meter can display positive and negative flow, and has multiple outputs: current , pulse, digital communication, HART.
9): The converter uses surface mount technology (SMT) with self-check and self-diagnosis functions.
10): There is no fluid component blockage in the measuring pipeline, no pressure loss, and low requirements for straight pipe sections. Types of electromagnetic flowmeters are as follows:
Parameter
Product Name | Electromagnetic Water Flow Meter, Wastewater Flow Meter |
Caliber | DN6-DN3000 |
Nominal Pressure | 0.6-4.0MPa(Special pressure can be customized ) |
Accuracy | 0.2%(DN15-DN600),0.5%(DN700-DN3000) |
Liner material | PTFE,PFA,F46,Neoprene ,Polyurethane |
Electrode type | SS316,HB,HC,TI,TA |
Ambient humidity | 5-100%RH(Relative humidity) |
Ambient temperature | -25℃ to +60℃ |
Measuring range | 1500:1,flow rate <15m/s |
Structure type | Integrate type,Remote type ,submersible type,ex-proof type |
Protection level | IP65,IP68 |
Ex-proof Mark | ExmdIIBT4 |
Product standard | JB/T9248-1999 electromagnetic flowmeter |
Selection of lining material
Lining material | The main performance | The scope of application |
PTFE | 1.1.The most stable chemical properties of plastics in a material that is resistant to boiling hydrochloric acid,sulfuric acid and aqua regia,but also resistant to concentrated acids and various organic solvents, intolerance chlorine trifluoride, liquid oxygen, high velocity liquid oxygen, ozone corrosion. 2.Poor wear resistance | Concentrated acid,alkali and other corrosive media |
PFA | Corrosion resistance with PTEF,strong anti-negative pressure | Can be used for negative pressure state |
F46 | 1.Corrosion resistance with PTEF. 2.Can withstand low wear andtear. 3.Strong anti-negative pressure. | With PTFE 2.Can be used for low abrasive media |
Neoprene | 1.Have excellent flexibility,a high degree of tensile force,good wear resistance. 2.Resistant to the general low concentrated acid, alkali,salt medium corrosion, corrosion resistant to oxidizing media. | Water, sewage, weakly abrasive mud, pulp |
Polyurethane | 1.Has excellent wear resistance (equivalent to 10 times the natural rubber). 2 acid, alkali performance is poor. 3Do not use water mixed with organic solvents. | Strong neutral wear pulp, coal slurry, mud and so on |
Flow Range
Flow rate—-flow comparison table | |||||||
0.01 | 1 | 2 | 3 | 4 | 5 | 15 | |
15 | 0.0064 | 0.6362 | 1.2723 | 1.9085 | 2.5447 | 3.1809 | 9.5426 |
20 | 0.0113 | 1.1310 | 2.2619 | 3.3929 | 4.5239 | 5.6549 | 16.9646 |
25 | 0.0177 | 1.7671 | 3.5343 | 5.3014 | 7.0686 | 8.8357 | 26.5072 |
40 | 0.0452 | 4.5239 | 9.0478 | 13.5717 | 18.0956 | 22.6195 | 67.8584 |
50 | 0.0707 | 7.0686 | 14.1372 | 21.2058 | 28.2743 | 35.3429 | 106.0288 |
65 | 0.1195 | 11.9459 | 23.8919 | 35.8377 | 47.7836 | 59.7295 | 179.1886 |
80 | 0.1810 | 18.0956 | 36.1911 | 54.2867 | 72.3823 | 90.4779 | 271.4336 |
100 | 0.2827 | 28.2743 | 56.5487 | 84.8230 | 113.0973 | 141.3717 | 424.1150 |
150 | 0.6362 | 63.6173 | 127.2345 | 190.8518 | 254.4690 | 318.0863 | 954.2588 |
200 | 1.1310 | 113.0973 | 226.1947 | 339.2920 | 452.3893 | 565.4846 | 1696.4600 |
300 | 2.5447 | 254.4690 | 508.9380 | 763.4070 | 1017.8760 | 1272.3450 | 3817.0351 |
350 | 3.4636 | 346.3606 | 692.7212 | 1039.0818 | 1385.4424 | 1731.8030 | 5195.4089 |
400 | 4.5239 | 452.3893 | 904.7787 | 1357.1680 | 1809.5574 | 2261.9467 | 6785.8401 |
450 | 5.7256 | 572.5553 | 1145.1105 | 1717.6658 | 2290.2210 | 2862.7763 | 8588.3289 |
500 | 7.0686 | 706.8583 | 1413.7167 | 2120.5750 | 2827.4334 | 3534.2917 | 10602.8752 |
600 | 10.1788 | 1017.8760 | 2035.7520 | 3053.6281 | 4071.5041 | 5089.3801 | 15268.1403 |
700 | 13.8544 | 1385.4424 | 2770.8847 | 4156.3271 | 5541.7694 | 6927.2118 | 20781.6354 |
800 | 18.0956 | 1809.5574 | 3619.1147 | 5428.6721 | 7238.2295 | 9047.7868 | 27143.3605 |
900 | 22.9022 | 2290.2210 | 4580.4421 | 6870.6631 | 9160.8842 | 11451.1050 | 34353.3157 |
1000 | 28.2743 | 2827.4334 | 5654.8668 | 8482.3002 | 11309.7336 | 14137.1669 | 42411.5008 |
1200 | 40.7150 | 4071.5041 | 8143.0082 | 12214.5122 | 16286.0163 | 20357.5204 | 61072.5612 |
1400 | 55.4177 | 5541.7694 | 11083.5389 | 16625.3083 | 22167.0778 | 27708.8472 | 83126.5416 |
1600 | 72.3823 | 7238.2295 | 14476.4589 | 21714.6884 | 28952.9179 | 36191.1474 | 108573.4421 |
1800 | 91.6088 | 9160.8842 | 18321.7684 | 27482.6525 | 36643.5367 | 45804.4209 | 137413.2627 |
2000 | 113.0973 | 11309.7336 | 22619.4671 | 33929.2007 | 45238.9342 | 56548.6678 | 169646.0033 |
Packing:
1. First, wrap the flowmeter in a plastic film, and then put it into an export wooden box with shockproof foam.
2. Professional packing personnel carry out packing.
Transport:
Support the designated freight forwarder, otherwise we will help you choose the right freight forwarder.
(Use FEDEX; Ups; DHL; TNT; EMS; etc.)
For more than 10 units, air, rail, and sea transportation are recommended.
Production time :
Below 20 sets: 3-5 working days.
Monthly production: more than 800 units
FAQ
1.Question: How is the quality of the electromagnetic flowmeter?
Answer: We have ISO, CE and ROSH certification, and a professional calibration team will perform a second 5-point calibration on the flowmeter before leaving the factory.
2. Q: Can I get samples?
Yes it is,
3.Q :: Can you give me the shortest delivery time?
Answer: yes
4. Question: How to install the electromagnetic flowmeter?
Answer: We can provide the installation manual and installation video of the flowmeter, please feel free to contact us.
5. Q: Can I visit your factory?
Answer: Of course,
Factory