Vortex Gas Flow Meter

Vortex Gas Flow Meter

Vortex Gas Flow Meter

The vortex gas flow meter produces a velocity flow meter based on the Karman vortex principle for measurement and metering of conventional gases, vapors and liquids. The vortex flow sensor has high precision and a wide range ratio. It has no moving parts in use, which can improve mechanical stability and reduce maintenance. Vortex is almost unaffected by the temperature, pressure and
 

Vortex flow meter types

Vortex Gas Flow Meter

Flow range

Flow meter flow range
(1) The flow range corresponding to the flowmeter of each specification when measuring liquid and normal gas:

specification

Liquid flow range(m³/h)

Ordinary gas flow range(m³/h)

Qmin

Qmax

Qmin

Qmax

DN15

0.3

3

3

30

DN20

0.6

6

6

60

DN25

1.0

12

10

120

DN32

1.2

15

12

180

DN40

1.5

31

15

275

DN50

2.2

49

25

458

DN65

3.6

84

40

730

DN80

5.5

127

55

1008

DN100

8.5

198

85

1550

DN125

13.3

309

140

2566

DN150

19.1

445

190

3483

DN200

34

790

340

6230

DN250

70

900

700

9000

DN300

130

2100

1200

21000

DN350

180

2500

1500

25000

DN400

230

3400

2000

34000

Note: The gas flow rate in the table is the volume flow rate under working conditions. (2) The flow rate of the above liquid and ordinary gas is a volume flow rate, and the density of the liquid or gas is known if the mass flow rate is measured. Calculated by the formula Qm=Qv*P:
Qm: Mass flow rate of the fluid to be measured (Kg/h)
Qv: Volume flow rate of the fluid to be measured (m3/h)
P: Density of the fluid to be measured (kg/m3)

(3)Steam is generally measured for its mass flow. The prerequisite is that the pressure and temperature of the steam must be known in order to know the density of the steam. Therefore, the mass flow rate of the steam is estimated by the volume flow using the above formula.

Product selection:
1. Before selecting the type, first determine the type and flow value of the measured medium (which can be an estimated value), and then select the vortex flowmeter according to the flow range corresponding to the vortex flowmeter in the measurement of different media. specification.
2. The flow rate of the measured medium in the pipeline must be within the flow range of the flowmeter. Otherwise, it cannot be used. The best is at 1/2~2/3 of the flowmeter flow range。
3. If the actual pipe diameter is larger or smaller than the selected flowmeter diameter, the shrinkage pipe or expansion pipe diameter should be used to ensure the correct use of the flowmeter.
4. According to the use of the vortex flowmeter, select the vortex signal output mode:
(1) When the measured medium is a compressible fluid, and the temperature and pressure of the field medium change greatly, it is recommended to use a vortex sensor with a pulse signal remote transmission and a flow totalizer with temperature and pressure compensation. Pressure transmitter, temperature transmitter or Pt100, need to be purchased separately.
(2) The flowmeter is installed in a well-equipped room without signal remote transmission. It only needs to read the flow value on the spot, and the flowmeter installation position is convenient for operation and data reading. It is recommended that the user select battery-powered direct reading on site. Vortex
flowmeter. However, if the flowmeter is installed outdoors and exposed to the atmosphere, the battery-powered direct-reading vortex flowmeter is generally not selected.
(3) When the installation environment of the flowmeter is poor or the installation location is not convenient for reading the flow value or centralized management on the spot, it is recommended to use the sensor that outputs the pulse signal and configure the flow totalizer, or with a standard current of 4~20mA. Output vortex transmitter。
(4) When it is necessary to observe the flow on the spot and transmit the signal at the same time, it is recommended to use the vortex transmitter with direct output and 4~20mA output at the same time
(5) When there is no need to read on site, only the standard signal is transmitted far away, it is recommended to use the vortex transmitter with 4~20mA standard current output.
5, according to the temperature of the measured medium, select high temperature or low temperature vortex flowmeter. The high temperature type of 250 ° C – 350 ° C is generally equipped with a heat sink.
6. Explosion-proof type vortex flowmeter is used for explosion-proof places.