Digital Turbine Flow Meter
Digital Turbine Flow Meter
2. Type: pulse type, integrated type, plug-in type (applicable to pipe diameter DN100 or above)
3. Material: SS304, SS316
4. Accuracy: 1%
1. Product Overview:
A digital turbine flow meter is a velocity flow meter used to measure the volumetric flow of low viscosity, uniform liquids flowing continuously through closed pipes. The sensor outputs a signal proportional to the liquid volume and is divided into current display type and pulse output type. The pulse type is used in conjunction with the corresponding flow totalizer or control equipment, and can be used to measure the instantaneous flow and accumulation of liquids. Flow and control. Liquid turbine instruments can measure water, high water content crude oil, oily sewage, diesel, gasoline, light oil, beer, beverage milk and other video-grade liquids. It has the characteristics of high precision, easy maintenance, simple installation and low cost of use. According to user needs, multiple output modes can be customized to achieve different functions: standard current output, pulse output, standard analog current output, fluid cumulative flow display, instantaneous flow display, etc.
2. Working principle and scope of application:
Digital turbine flow meter is a device widely used in industrial processes to accurately measure liquid flow. It is used to measure the volume of liquid passing through a device over a specific period of time. The flow meter consists of an impeller, and the rotation speed of the impeller is proportional to the flow rate of the fluid. The number of revolutions of the turbine is counted by a digital sensor connected to an electronic output device to display the measurement reading.
This type of meter measurements are very accurate, reliable, and have fast response times. It provides precise results even when used with highly viscous fluids or liquids containing suspended particles. And it is easy to install and does not require daily maintenance.
The equipment has become an integral part of many industries, including chemical, petroleum, food processing and water treatment plants. It helps optimize production processes, control fluid flow and monitor resource usage. It is a cost-effective solution that increases efficiency, reduces production costs and improves overall output quality.
In conclusion, liquid turbine flowmeters are a valuable investment for manufacturing industries. It provides accurate, real-time data that helps enhance workplace safety, reduce downtime and save costs.
3. Product features:
※High accuracy, generally up to ±0.5%, high-precision type up to ±0.2%;
※With good repeatability, such as frequent calibration or online calibration, extremely high accuracy can be achieved. It has three-point correction of the instrument coefficient during settlement, intelligently compensates for the nonlinearity of the instrument coefficient, and can perform on-site correction;
※All valid data will not be lost within 10 years of power outage;
※Wide range, the diameter of medium and large pipes can reach 1:20, and the diameter of small pipes can reach 1:10;
※Compact and lightweight structure, easy installation and maintenance, large circulation capacity;
※Suitable for high-voltage measurement, no holes are required on the instrument body, making it easy to make high-voltage instruments;
There are many types of special sensors, which can be designed according to the special needs of users, such as low-temperature type, two-way type, underground type, special type for sand mixing, etc.
※It can be made into a plug-in type, suitable for large diameter measurement, with small pressure loss and low price. The instrument can be taken out without cutting off the flow, and is easy to install and maintain;
4.Converter menu item table:
Number | Caption | Meaning | Parameter options or range |
1 | Q – Unit
m3/h | Select flow unit Default (0) | 0: m/h 6: t/h3 1: m/m 7: t/m3 2: l/h 8: kg/h 3: l/m 9: kg/m 4: SG/h 10: lb/h 5: SG/m 11: lb/m |
2 | Q – Mode Qw actual | Select to Algorithm Default (0) | 0: conventional volume flow 1. Conventional mass flow |
3 | Q – Factor [P/m3] 3600.00 | Set the discharge coefficient | Set the meter coefficient in P/m3 Default (3600) |
4 | Density [kg/m3] 1000.0 | Set the density of the fluid | The unit of density value of the fluid is set to be kg/m3 Default (1000.0) |
5 | Q – 20 mA m3/h 1000.0 | Set the Upper flow limit Default(1000) | The flow value when the 20mA current signal is output must be set and must not be 0.Units are the same as flow units |
6 | Q the Cut – Zero [0-50]% 0.0 | Set the Flow min limit Default (0.0) | Cut off by % of full discharge Values range from 0 to 50 |
7 | Damp (Only TB2WE) | Set the Damp time of current output default(4) | Set the damping time of current output, which is used to avoid the fluctuation of output current flow. The range is 2~32, and the unit is seconds |
8 | Hart Address / Com Address 0 | Set the HART sub-address or the modbus-rs485 address Default (0) | Default (0) The Two Wire 2WE model is located in HART equipment sub-address, range 0-15 The Three-wire model 3WE is equipped with the meter address of 485, ranging from 0 to 255 |
9 | COM Set (Only TB3WE) COM=OFF | Set baud rate Default (“OFF”) | Only TB3WE,”OFF” to turn off communication to save power. “4800” and ”9600” is the band rate items; |
10 | Clear Q | Reset Qt | input password “70” and hand in to clear the accumulator |
5.Flow range table:
Nominal diameter (mm) | Normal flow range and extended flow range | |
(m3/h) | (m3/h) | |
4 | 0.04~0.25 | 0.04~0.4 |
6 | 0.1~0.6 | 0.06~0.6 |
10 | 0.2~1.2 | 0.15~1.5 |
15 | 0.6~6 | 0.5~5 |
20 | 0.8~8 | 0.45~9 |
25 | 1~10 | 0.5 ~10 |
32 | 1.5~15 | 0.8~1 |
40 | 2~20 | 1~20 |
50 | 4~40 | 2~40 |
65 | 7~70 | 5~70 |
80 | 10~100 | 7~100 |
100 | 20 ~20 | 10~200 |
125 | 25~250 | 13~250 |
150 | 30~300 | 15~300 |
200 | 80~800 | 40~800 |
Accuracy level | ±0.5% | ±1% |
6.Thread connection size:
DN4~DN10 threaded connection sensor (including straight pipe section) | DN15~DN50 threaded connection sensor | |||||
Caliber (mm) |
L(mm) |
H(mm) |
G | |||
Pulse type | Explosion-proof pulse type | 4-20ma output type | ||||
4 | 225 | 140 | 145 | 145 | G1/2 | |
6 | 225 | 140 | 145 | 145 | G1/2 | |
10 | 345 | 145 | 150 | 145 | G1/2 | |
15 | 75 | 145 | 150 | 150 | G1 | |
20 | 80 | 150 | 155 | 155 | G1 | |
25 | 100 | 155 | 160 | 160 | G1 1/4 | |
32 | 140 | 175 | 180 | 180 | G2 | |
40 | 140 | 180 | 185 | 180 | G2 | |
50 | 150 | 185 | 190 | 190 | G2 1/2 | |
Remarks: Thread standards can be customized, and various international thread standards are accepted. |
7.Flange connection size table:
| |||||
Flange connection diagram | |||||
Caliber (mm) |
L(mm) |
H(mm) |
Standard pressure | ||
Pulse type | Explosion-proof pulse type | 4-20ma output type | |||
15 | 75 | 175 | 180 | 180 |
4.0Mpa |
20 | 80 | 185 | 190 | 190 | |
25 | 100 | 200 | 205 | 205 | |
32 | 140 | 210 | 215 | 215 | |
40 | 140 | 215 | 220 | 220 | |
50 | 150 | 230 | 235 | 235 | |
65 | 170 | 255 | 260 | 260 |
1.6Mpa |
80 | 200 | 260 | 265 | 265 | |
100 | 220 | 285 | 290 | 290 | |
125 | 250 | 310 | 315 | 315 | |
150 | 300 | 345 | 350 | 350 | |
200 | 350 | 395 | 400 | 400 | |
Remarks: Flange standards and pressure levels, flow meter sensor dimensions, etc. can be customized. |
8.Installation structure diagram:
|
1. The filter 2. Straight pipe before 3. The impeller 4. The impeller preamplifier 5. Case 6. After the straight pipe The whole table structure |
|
DN15 ~ 40 sensor structure diagram and installation size 1. Case 2. Guide before a 3. impeller 4. The impeller leads to a 5. After preamplifier |
|
DN50 ~ 200 sensor structure diagram and installation size 1. The ball bearing 2. ball bearing guide before a 3. The flange 4. flange shell 5. Preamplifier 6. Impeller 7. bearing 8. Bearing axis |
9.Workshop sensor production drawing:
10.Workshop flow sensor video:
11.FAQ:
1. Question: What are the sensor materials?
A: Sensor materials include: SS304 and SS316.
2. Question: What level of accuracy can it achieve?
A: Our normal accuracy standard is 0.5%, and the maximum accuracy can reach 0.2% (special customization is required).
3.Q: What is the minimum order quantity PCS?
A: Our MOQ is 1PCS.
4. Q: If payment is completed, how long is the delivery time?
A: After we receive payment, production of less than 50PCS is expected to take 7 working days. Delivery time: Our sales representative can calculate the delivery time based on the quantity you purchase and the shipping method you choose.
5.Q: What are the payment methods?
A: The payment methods we support: TT payment, RMB payment, Western Union payment, credit card online payment, LC payment.