Variable Flow Meter

Variable Flow Meter

Variable Flow Meter

Variable flow meter ,tube float flowmeter, also known as the “metal tube rotameter”, is a measuring instrument commonly used in the industrial automation process management to measure the variable area flow. Being featured with characteristics of small size, wide application range, convenient usage, etc., it is designed for measuring the flows of liquids, gases and steam, especially applicable for measurement of low flow speed and small flow rate.
 

Diameter (mm)

Flow range

Pressure loss KPa

Accuracy level

15

Water L/h

Air m3/h

Water

Air

Normal temperature type

Anticorrosive

Normal temperature type

,Anticorrosive

   

2.5—25

2.5—-25

0.07–0.7

0.07—0.7

6.5

7.1

1.5
       2.5

4.0—40

4.0—40

0.11—1.1

0.11—1.1

7.2

3.6—63

6.3—63

0.18—1.8

0.18—1.8

6.6

7.3

10—100

10—100

0.28—2.8

0.28—2.8

7.5

16—-160

16—160

0.4—4.0

0.4—4.0

6.8

8.0

25—-250

25—-250

0.7—7.0

0.7—-7.0

7.2

10.8

40—400

40—400

1.0—10

1.0—-10

8.6

10.0

63—630

——-

1.6—16

———

11.1

14.0

25

100—1000

63—630

3.0—30

1.6—-16

7.0

7.7

160—1600

100—1000

4.5—45

3.0—30

8.0

8.8

250—2500

160—-1600

7.0—-70

4.5—-45

10.8

12.0

400—4000

250—2500

11—110

7.0—–70

15.8

19.0

50

630–6300

400—4000

18—180

11—–110

8.1

8.6

1000—10000

630—6300

25—-250

18—-180

11.0

10.4

1600—16000

1000—10000

40—-400

25—-250

17.0

15.5

80

2500—25000

1600—16000

60—600

40—-400

8.1

8.0

4000—40000

2500–25000

100—-1000

60—600

9.5

13.0

100

6300—63000

4000—40000

200—2000

100—-1000

10.0

11.0

    

10000—100000

——-

300—-3000

——–

Parameter

Ange of flow

Liquid  1.0~150000L/h

Gas 0.03~4000m3/h

Measure Ratio

101,201(special)

Precision

Grade 1.5, Grade 1.0 (special)

Pressure rating

DN15~DN50:4.0MPa;DN80~DN200:1.6MPa

DN15~DN50:25MPa;DN80~DN200:16MPa

Medium temperature

Standard:-80℃ ~+200℃ ,PTFE: 0℃ ~+85℃,high temperature:400℃

Power  supply

Standard: 24VDC(12~36VDC); AC type: 85~265VAC 50Hz; Battery type:3.6V@4AH

Output signal

Collector open circuit output(max 100mA@30VDC internal impedance 100Ω

Relay output(max 5A@250VAC)

Environmental temperature

Liquid crystal type:-30℃ ~85℃
     Pointer type: -40℃ ~120℃

Storage requirement

Temperature:-40℃ ~85℃ humidity:≤85%

Connection mode

Flange connecting. Flange standard :GB/T9119-2000; User’s appointment allowed

Cable interface

M20×1.5

Housing protection grade

Ip65

Mark of explosion-proof

Intrinsic safety type:ExiaIICT6 explosion-proof type:ExdIICT6

Pressure loss

7kPa~70kPa

Viscosity of medium

DN15:η<5mPa.s DN25:η<250mPa.s DN50~DN150:η<300mPa.s

Contact material

R1:304,1Cr18Ni9Ti; Ro:316,0Cr18Ni12Mo2Ti; RL:316L,00Cr17Ni14Mo2Ti;

Ti:Titanium alloy; Rp:PTFE lining

Installation requirements
 
In the picture: 5XDN and 250 are front and rear straight pipe segments, 100 is reserved for excitation filter.

 
Precautions for installation:
1. Before installation of the Variable Flow Meter, the process pipeline should be purged to prevent the stranded ferromagnetic substances in the pipeline from adhering to the instrument.It affects the performance of the meter and can even damage the meter.If not, a magnetic filter should be installed at the inlet of the meter.The affected instrument itself does not participate in the air sweep before production, so as not to damage the instrument.
2. Before the instrument is installed, all package should be removed and checked for transportation damage, and the shell should be opened to remove the filling of the fixed pointer.
3. The installation of the Variable Flow Meter can be divided into vertical installation and horizontal installation. In the case of vertical installation, the Angle between the center vertical line and the plumb line should be less than 2; in the case of horizontal installation, the Angle between the horizontal center and the horizontal leader should be less than 2.
4. The upstream and downstream pipes of the instrument should be the same as the diameter of the instrument, and the connecting flange or thread should be matched.The length of the straight pipe section on the instrument should be 5 times of the nominal diameter of the instrument, and the length of the downstream straight pipe section should be no less than 250mm.
5. Because the instrument is through the magnetic Shao to transfer signals, so in order to ensure the performance of the instrument. No ferromagnetic material is allowed to exist at least 10m around the installation.
6. Gauges that measure gases are calibrated at a particular pressure.If gas is vented directly into the atmosphere at the outlet of the meter, it will create pressure drop at the float and cause distortion. If this happens, a valve should be installed at the outlet of the meter.
7. Gauges installed in pipelines shall not be subjected to pressure, and the inlet and outlet of the instrument shall be properly supported by pipes to minimize the stress of the instrument.
8. When installing PTFE-lined instruments, special care should be taken, as PTFE will deform under pressure.So the flange nut should not be screwed too tightly at will.
9. With liquid crystal display instrument, installation should try to avoid direct sunlight display, thereby reducing the life of the liquid crystal display
10. Low temperature medium measurement, need to choose the jacket type.

FAQ
 1. How about your delivery time?
 Generally, it will take 5 to 10 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.
 2. Can you produce according to the samples?
 Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
 3. What’s your payment method?
 Paypal, T/T, L/C, Western Unions, are available.
 4.How do you pack your products?
 We pack the goods in wooden cases or according to customer’s requirement.
 5.How can I order a sample?
 You can talk to customer service and he will help you.
 6.What is the warranty for your product ?
 Warranty: 1 years.

Register an Interest


Provide Your Information



ICTC ICTC