Insertion Vortex Flow Meter

Insertion Vortex Flow Meter

Insertion Vortex Flow Meter

Insertion vortex flow meter, it is suitable for big diameter pipe size .It is not affected by the temperature, pressure, viscosity and composition of the medium, at the same time, it is not blocked, not stuck, not easy to scale, is resistant to high temperature and high pressure, is safe and explosion-proof, and is suitable for harsh environments. The vortex flow meter flow meter is divided into
 

Plug-in vortex flow meter Basic technical parameters:

◇Nominal diameter: 15~2500mm

◇Measuring medium: liquid, gas, steam

◇Medium temperature: -40~350℃ (capacitive type: -60~450℃)

◇Connection mode: flange card mounting type, flange type, plug-in type

◇Nominal pressure: 2.5MPa, 4.0MPa, 6.9MPa, 25MPa

◇Accuracy grade: 1.0 (liquid, gas), 1.5 (steam), 2.5 (plug-in)

◇Repeatability: ≤0.3%, 0.5%, 1.0%

◇Body material: stainless steel 304, stainless steel 316L

◇Load resistance: <750Ω

◇Power supply: 24VDC, 3.6V lithium battery

◇Output signal: pulse frequency, 4~20mADC, RS485, Hart protocol

◇Range of velocity: liquid 0.5~6m/s, gas 5~60m/s

 ◇Explosion-proof grade: iaⅡCT1—T6 intrinsically safe type (used with Zener safety barrier)

◇Protection level: IP65, IP67, IP68

vortex flowmeter

More vortex flow meters

Insertion Vortex Flow Meter

Flow range

Instrument caliber(mm)

liquid

Gas

 

Measuring range(m3/h)

Output frequency range(Hz)

Measuring range(m3/h)

Output frequency range(Hz)

15

0.3~5

24~400

4~20

352~1761

20

0.6~10

23~382

6~30

254~1273

25

1.2~16

21~320

8~55

161~1112

32

1.8~20

18~200

10~120

97~1172

40

2~40

10~190

27~205

134~1018

50

3~60

8~150

35~380

87~952

65

4~85

6~120

60~640

71~764

80

6.5~130

4.1~82

86~1100

54~696

100

15~220

4.7~69

133~1700

42~548

125

20~350

3.2~57

150~2000

26~346

150

30~450

2.8~43

347~4000

34~392

……

    

300

95~2000

1.2~24

1360~18000

16~216

 

The installation method
(1) Insertion vortex flow meter installation as shown below, when pressure or temperature compensation is required, a separate pressure transmitter and temperature transmitter should be provided. The position of the pressure tapping hole is set at 3 to 5DN downstream of the sensor, and the diameter of the pressure tapping hole is 6 to 13 mm. The temperature measurement point is set at 6~8DN downstream of the sensor. (as shown in Figure 3 above)
(2) When the flanged-mounted vortex flowmeter is installed on the pipeline, in order to ensure accurate and reliable installation, the vortex flowmeter and the card-mounted flange can be bolted first, and then the clamped flange is welded. On the pipe. In order to prevent the vortex flowmeter from being damaged due to excessive temperature during welding, spot welding should be performed first, then the vortex flowmeter should be removed and then welded.
(3) In order to facilitate maintenance and inspection, a bypass pipe may be provided, which is installed on the vortex flowmeter and outside of the downstream straight pipe section to prevent it from affecting the measurement of the vortex flowmeter.
(4) The installation of the anti-fall type vortex flowmeter shall be carried out in accordance with the relevant provisions of GB383.15-2000 “Electrical Equipment for Explosive Gas Atmospheres”, Part 15: “Electrical Installation of Hazardous Locations (Excluding Coal Mines)”.

Payment Terms  
1.Loading Port: Shanghai China
2. Samples Leading Time: 3-7 working days
3. Delivery Time: Within 7-15 days after payment
4.Payment:  T/T, Western Union

Register an Interest