Magnetic Flow Meter Application
Magnetic Flow Meter Application
Advantage :
1. JYLDE electromagnetic flowmeter adopts high stability and high efficiency, and is designed with a wide input range of multiple sets of isolated power switches.
2. Easy to operate, JYLDE electromagnetic flowmeter is automatically set according to the range of 0~10m/s without changing the range.
3. With automatic operation function, the average flow is large, and it is easy to calibrate the flowmeter.
Application:
The JYLDE series of intelligent electromagnetic flowmeters are manufactured according to the law of electromagnetic induction. They are used to measure the volumetric flow of conductive liquids in pipelines, water, sewage, mud, mud, acid, alkali, salt and food slurry, and are widely used.
Types of magnetic flow meter
Parameter
Max flow rate | 15m/s |
Accuracy | ±0.5% ,±0.2% |
Fluid conductivity | >5μS/cm |
Nominal pressure | 0.6Mpa,1.0Mpa,1.6Mpa,4.0Mpa(customized for high |
Caliber | DN6-DN3000 |
Liner material | PTFE,PFA,F46,Neoprene ,Polyurethane |
Electrode | SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum-iridium |
Ambient humidity | 5-100%RH(Relative humidity) |
Ambient temperature | -25℃ to +60℃ |
Measuring range | 1500:1,flow rate <15m/s |
Structure type | Integrate type,Remote type ,Insertion type ,ex-proof type |
Protection level | IP65(standard ) ,IP68(Optional ) |
Ex-proof Mark | ATEX |
Power supply | 24V ,220V ,3.6V battery |
Signal output | 4-20Ma , pulse |
Communication protocol | RS485(Modbus ),Hart |
Product standard | JB/T9248-1999 electromagnetic flowmeter |
Selection of lining material
Electrodes material | Corrosion resistance |
SS316 | Applicable to industrial/municipal drinking water, wastewater and low corrosive mediums. |
Hastelloy B | It has good corrosion resistance to all concentrations of hydrochloric acid below the boiling point, and is also resistant to oxidizing acids, alkalis, and non-oxidizing salt solutions such as sulfuric acid, phosphoric acid, and organic acids. |
Hastelloy C | It is resistant to oxidizing acids, such as nitric acid, mixed acids, and also resistant to oxidizing salts. If the hypochlorite solution is higher than normal temperature, seawater will corrode. |
Titanium | It can withstand the corrosion of sea water, various chlorides and hypochlorites, oxidizing acids, organic acids, and alkalis, but is not resistant to the corrosion of relatively pure reducing acids. However, if the acid contains an oxidizing agent, the corrosion is greatly reduced. |
Tantalum | It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid and alkali, it is resistant to corrosion by almost all chemical media |
Flow Range
Flow rate—-flow comparison table | |||||||
0.01 | 1 | 2 | 3 | 4 | 5 | 15 | |
15 | 0.0064 | 0.6362 | 1.2723 | 1.9085 | 2.5447 | 3.1809 | 9.5426 |
20 | 0.0113 | 1.1310 | 2.2619 | 3.3929 | 4.5239 | 5.6549 | 16.9646 |
25 | 0.0177 | 1.7671 | 3.5343 | 5.3014 | 7.0686 | 8.8357 | 26.5072 |
40 | 0.0452 | 4.5239 | 9.0478 | 13.5717 | 18.0956 | 22.6195 | 67.8584 |
50 | 0.0707 | 7.0686 | 14.1372 | 21.2058 | 28.2743 | 35.3429 | 106.0288 |
65 | 0.1195 | 11.9459 | 23.8919 | 35.8377 | 47.7836 | 59.7295 | 179.1886 |
80 | 0.1810 | 18.0956 | 36.1911 | 54.2867 | 72.3823 | 90.4779 | 271.4336 |
100 | 0.2827 | 28.2743 | 56.5487 | 84.8230 | 113.0973 | 141.3717 | 424.1150 |
150 | 0.6362 | 63.6173 | 127.2345 | 190.8518 | 254.4690 | 318.0863 | 954.2588 |
200 | 1.1310 | 113.0973 | 226.1947 | 339.2920 | 452.3893 | 565.4846 | 1696.4600 |
300 | 2.5447 | 254.4690 | 508.9380 | 763.4070 | 1017.8760 | 1272.3450 | 3817.0351 |
350 | 3.4636 | 346.3606 | 692.7212 | 1039.0818 | 1385.4424 | 1731.8030 | 5195.4089 |
400 | 4.5239 | 452.3893 | 904.7787 | 1357.1680 | 1809.5574 | 2261.9467 | 6785.8401 |
450 | 5.7256 | 572.5553 | 1145.1105 | 1717.6658 | 2290.2210 | 2862.7763 | 8588.3289 |
500 | 7.0686 | 706.8583 | 1413.7167 | 2120.5750 | 2827.4334 | 3534.2917 | 10602.8752 |
600 | 10.1788 | 1017.8760 | 2035.7520 | 3053.6281 | 4071.5041 | 5089.3801 | 15268.1403 |
700 | 13.8544 | 1385.4424 | 2770.8847 | 4156.3271 | 5541.7694 | 6927.2118 | 20781.6354 |
800 | 18.0956 | 1809.5574 | 3619.1147 | 5428.6721 | 7238.2295 | 9047.7868 | 27143.3605 |
900 | 22.9022 | 2290.2210 | 4580.4421 | 6870.6631 | 9160.8842 | 11451.1050 | 34353.3157 |
1000 | 28.2743 | 2827.4334 | 5654.8668 | 8482.3002 | 11309.7336 | 14137.1669 | 42411.5008 |
1200 | 40.7150 | 4071.5041 | 8143.0082 | 12214.5122 | 16286.0163 | 20357.5204 | 61072.5612 |
1400 | 55.4177 | 5541.7694 | 11083.5389 | 16625.3083 | 22167.0778 | 27708.8472 | 83126.5416 |
1600 | 72.3823 | 7238.2295 | 14476.4589 | 21714.6884 | 28952.9179 | 36191.1474 | 108573.4421 |
1800 | 91.6088 | 9160.8842 | 18321.7684 | 27482.6525 | 36643.5367 | 45804.4209 | 137413.2627 |
2000 | 113.0973 | 11309.7336 | 22619.4671 | 33929.2007 | 45238.9342 | 56548.6678 | 169646.0033 |
FAQ
Q:How long will you give me the reply ?
A: We will reply you in 1 hours as soon as possible , with in 10 hours if at night .
Q:Do you offer OEM service ?
A:Yes ,Pleasure feel free to send us your requirements .
Q: What is the material of the electromagnetic flowmeter?
A: Carbon steel, 304 stainless steel, 316 stainless steel.
Q:How about warranty time of your products ?
A:2 years .
Why chose us
1. Our flowmeters have been exported to more than 40 countries, and we have established long-term and stable cooperative relations with more than 30 flowmeter buyers.
2. Two QC inspections before 100% shipment.
3. ISO, CE, SGS standards and high-quality products with highly competitive prices.
4. All instruments have been 100% approved by the National Bureau of Metrology.
Certification
Factory