Milk Flow Meter
Milk Flow Meter
1. JYLDE electromagnetic flowmeter is suitable for all sanitary media. For conductivity tests with a flow rate greater than 5, changes in conductivity do not affect the stability of the flowmeter.
2. Use the world’s best integrated circuit to eliminate the influence of the excitation switch, and use the excitation current compensation method to finally achieve the best stability of the product.
3. The flowmeter has no mechanical and moving parts, and no maintenance is required.
4. Since the lining and electrode are in contact with the measured medium, they have good corrosion resistance and wear resistance, so they have a wide range of applications.
5. When measuring oily mixed media (conductive) or a medium covered with a layer of conductive material on the electrode surface, you can choose a switchable (frosted) electrode.
6. The flowmeter has long-term stable high-precision measurement. It is not affected by the physical properties of the fluid. The measurement accuracy can be up to 0.2%.
7. With high efficiency and high stability, a wide input range of multiple sets of isolated switching power supplies is designed.
Advantage :
1.Self-checking function
2.High definition LED display
3.16-Bit embedded microprocessor
4.Ultra-low EMI Switching power supply
5.Using international advanced single Chip microcomputer
Working Conditions
Ambient temperature | -20- 55C |
Ambient humidity | 5% – 95% |
Power supply | AC220V±10% |
Operating power | <10 W |
Maximum working temperature | 70–140C |
Application:
It is widely used for the measurements of acid , alkali, Salt solution , water , sewage,corrosive liquids, and fluid flow of mod ,pulp , etc .
Types of efm flow meter
Parameter
Flow measurement range and range ratio | Display range ratio 1:150, precision range ratio Leve0.3 1:4, Leve0.5 1:10, Leve1.0 1:20 |
Velocity range | ≤15m/s |
Dielectric conductivity | ≥5μs/cm |
Accuracy | 0.2%,0.5% |
Medium temperature | -20℃~60℃,-20℃~90℃,-20℃~100℃,-20℃~180℃ |
Material | Carbon steel , 304 or 316 stainless steel |
Flange connection Way | Flange connection , Tri-clamp , thread ,wafer |
pressure | 1.6,2.5,6.4,16,26,42Mpa |
Using the environment | The temperature -20℃~+50℃ Humidity≤85%,Air pressure 86kpa~106kpa |
The output signal | Frequency output 0-5KHz Voltage output 1-5v |
The power supply | external power supply 220VAC±15%; external power supply 24VDC±5%(optional)Lithium battery power supply |
Power consumption | ≤15w(external power supply) |
Protection grade | IP67,IP68 |
The lining material | Polyurethane rubber, neoprene, ptfe, F46, etc |
Electrode materials | 316L, hastelloy HB, hastelloy HC, titanium, platinum, etc |
Special electrode material | Such as: titanium, tantalum, platinum and other rare metal materials |
The installation type | The whole body,Separate body, Insertion type |
Explosion-proof grade | ExmdibIIBT4 |
Selection of lining material
Lining material | The main performance | The scope of application |
PTFE | 1.The most stable chemical properties of plastics in a material that is resistant to boiling hydrochloric acid,sulfuric acid and aqua regia,but also resistant to concentrated acids and various organic solvents, intolerance chlorine trifluoride, liquid oxygen, high velocity liquid oxygen, ozone corrosion. 2.Poor wear resistance | Concentrated acid,alkali and other corrosive media |
PFA | Corrosion resistance with PTEF,strong anti-negative pressure | Can be used for negative pressure state |
F46 | 1.Corrosion resistance with PTEF. 2Can withstand low wear and tear. 3,Strong anti-negative pressure. | With PTFE 2.Can be used for low abrasive media |
Neoprene | 1.Have excellent flexibility,a high degree of tensile force,good wear resistance. 2.Resistant to the general low concentrated acid, alkali,salt medium corrosion, corrosion resistant to oxidizing media. | Water, sewage, weakly abrasive mud, pulp |
Polyurethane | 1.Has excellent wear resistance (equivalent to 10 times the natural rubber). 2 acid, alkali performance is poor. 3.Do not use water mixed with organic solvents. | Strong neutral wear pulp, coal slurry, mud and so on |
Flow Range
Flow rate—-flow comparison table | |||||||
0.01 | 1 | 2 | 3 | 4 | 5 | 15 | |
15 | 0.0064 | 0.6362 | 1.2723 | 1.9085 | 2.5447 | 3.1809 | 9.5426 |
20 | 0.0113 | 1.1310 | 2.2619 | 3.3929 | 4.5239 | 5.6549 | 16.9646 |
25 | 0.0177 | 1.7671 | 3.5343 | 5.3014 | 7.0686 | 8.8357 | 26.5072 |
40 | 0.0452 | 4.5239 | 9.0478 | 13.5717 | 18.0956 | 22.6195 | 67.8584 |
50 | 0.0707 | 7.0686 | 14.1372 | 21.2058 | 28.2743 | 35.3429 | 106.0288 |
65 | 0.1195 | 11.9459 | 23.8919 | 35.8377 | 47.7836 | 59.7295 | 179.1886 |
80 | 0.1810 | 18.0956 | 36.1911 | 54.2867 | 72.3823 | 90.4779 | 271.4336 |
100 | 0.2827 | 28.2743 | 56.5487 | 84.8230 | 113.0973 | 141.3717 | 424.1150 |
150 | 0.6362 | 63.6173 | 127.2345 | 190.8518 | 254.4690 | 318.0863 | 954.2588 |
200 | 1.1310 | 113.0973 | 226.1947 | 339.2920 | 452.3893 | 565.4846 | 1696.4600 |
300 | 2.5447 | 254.4690 | 508.9380 | 763.4070 | 1017.8760 | 1272.3450 | 3817.0351 |
350 | 3.4636 | 346.3606 | 692.7212 | 1039.0818 | 1385.4424 | 1731.8030 | 5195.4089 |
400 | 4.5239 | 452.3893 | 904.7787 | 1357.1680 | 1809.5574 | 2261.9467 | 6785.8401 |
450 | 5.7256 | 572.5553 | 1145.1105 | 1717.6658 | 2290.2210 | 2862.7763 | 8588.3289 |
500 | 7.0686 | 706.8583 | 1413.7167 | 2120.5750 | 2827.4334 | 3534.2917 | 10602.8752 |
600 | 10.1788 | 1017.8760 | 2035.7520 | 3053.6281 | 4071.5041 | 5089.3801 | 15268.1403 |
700 | 13.8544 | 1385.4424 | 2770.8847 | 4156.3271 | 5541.7694 | 6927.2118 | 20781.6354 |
800 | 18.0956 | 1809.5574 | 3619.1147 | 5428.6721 | 7238.2295 | 9047.7868 | 27143.3605 |
900 | 22.9022 | 2290.2210 | 4580.4421 | 6870.6631 | 9160.8842 | 11451.1050 | 34353.3157 |
1000 | 28.2743 | 2827.4334 | 5654.8668 | 8482.3002 | 11309.7336 | 14137.1669 | 42411.5008 |
1200 | 40.7150 | 4071.5041 | 8143.0082 | 12214.5122 | 16286.0163 | 20357.5204 | 61072.5612 |
1400 | 55.4177 | 5541.7694 | 11083.5389 | 16625.3083 | 22167.0778 | 27708.8472 | 83126.5416 |
1600 | 72.3823 | 7238.2295 | 14476.4589 | 21714.6884 | 28952.9179 | 36191.1474 | 108573.4421 |
1800 | 91.6088 | 9160.8842 | 18321.7684 | 27482.6525 | 36643.5367 | 45804.4209 | 137413.2627 |
2000 | 113.0973 | 11309.7336 | 22619.4671 | 33929.2007 | 45238.9342 | 56548.6678 | 169646.0033 |
FAQ
Q: How about the quality of the magnetic flow meter .
A: We have ISO , CE , Atex , we can send you our certification test of ours to your company.
Q:Could we visit your factory .
A: Yes , sure . If you need , we will help you to visit our factory .
Q: Does your company offer other products besides mag flow meters?
A:Turbine flow meter , vortex flow meter , ultrasonic flow meter , orifice flow meter etc .
Q:Could you provide me the shortest lead time ?
A: We have materials in stock now . If it is the regular model ,that is in stock,
Factory
Henan Junyuan Automation is a high-tech enterprise specializing in the research, development and production of flow meters such as electromagnetic flowmeters and vortex flowmeters.
The company has advanced production technology and perfect after-sales service system. The main products are: electromagnetic flowmeter, vortex flowmeter, turbine flowmeter, ultrasonic flowmeter, throttling device, rotameter, complete set of automatic instrumentation, widely used in metallurgy, water supply and drainage, electric power, mining, petroleum, chemical, papermaking , medicine, light industry, environmental protection and other industries.Our philosophy: the pursuit of excellence, professionalism.Our aim: to survive by quality, to win the word of mouth by service.