Radar Level Gauge
Radar Level Gauge
Measuring range: 0~20m
Connection process: thread/flange
Medium temperature: (-40~120)℃
1. Product overview:
Radar level gauge JYDAR-6X series is that the electromagnetic wave propagates in space at the speed of light, and when it encounters the surface of the measured medium, part of its energy is reflected back and received by the same antenna. According to the time interval between two pulses, the distance from the antenna to the surface of the measured medium is calculated.
2. Product principle:
The antenna system transmits and receives very short microwave pulses with very low transmitted energy. Radar waves travel at the speed of light. The running time can be converted to a level signal by electronic components. A special time-expansion method ensures stable and accurate measurements over very short periods of time. Even if there are false echoes under complex working conditions, the latest micro-processing technology and debugging software can be used to accurately analyze the echo of the material position.
※Enter:
The antenna receives the reflected microwave pulses and sends them to the electronic circuit. A microprocessor processes the signal and recognizes the echoes generated by the micropulses on the material surface.
The correct echo signal identification is completed through intelligent software, and the accuracy can reach millimeter level. The distance D from the material surface is proportional to the time interval of the pulses:
D=C*T/2
where C is the speed of light, since the distance E of the empty can,
The material/level position L is then:
L=E-D
※Output:
By entering the empty tank height E (= zero), the full tank height F (= full scale) and some application parameter settings, the instrument is automatically adapted to the measurement environment.
Corresponds to 4-20mA output.
3.Degree of protection
How to ensure that the installation meets the requirements of IP68 as shown in the figure: Please ensure that the sealing head is not damaged.
The instrument cable is not damaged. Please make sure that the cables used meet the requirements of the electrical connection regulations. in progress
The meter fully meets the requirements of protection class IP68, please ensure the waterproofness of the cable sealing head.
Before entering the electrical interface, bend the cable downwards to ensure that water will not flow into the housing, see ①
Please tighten the cable gland, see ②
Please plug the unused electrical interface with a blind plug, see ③
4. Installation requirements:
Recommended distance from the wall to the exterior wall where the spool is installed (1).
The minimum distance from the pipe wall to the tank is 1/6 of the tank diameter, minimum 400mm.
It cannot be installed above the feed inlet, and cannot be installed in the center position.
5.Features:
※The beam angle is small, the energy is concentrated, and it has stronger anti-interference ability, which greatly improves the measurement accuracy and reliability.
※ The antenna is small in size and easy to install.
※ The measurement blind area is smaller, and the measurement effect for small tanks is also very good.
※ The wavelength is shorter, which is more suitable for the level measurement of small particle materials.
※ Non-contact measurement, no wear, no pollution.
※ The output signal can choose two-wire system (4-20) mA@HART and four-wire system RS485@MODBUS protocol, and the four-wire system power supply is as low as 12VDC.
6.Radar level gauge Parameters:
Unit | Code | Parameters | ||
Instrument Type | P | Standard | ||
D | Flameproof | |||
I | Intrinsically Safe Explosion-Proof ( Exia IIC T6 Ga) | |||
Housing/Protection Grade | L | Die-Casting Aluminium With Epoxy Coating/IP68 | ||
G | Die-Casting Aluminium With Epoxy Coating Dual Chamber/IP67 | |||
Material | 6 | Stainless Steel 316L | ||
7 | Four Fluorine PTFE | |||
8 | PP | |||
Y | Special Custom | |||
Sensor | A | Rod Type PVDF | C | (200mm)Rod Type PTFE |
B | (150mm)Rod Type PTFE | D | (250mm)Rod Type PTFE | |
Process Connection | G | G 1½A Thread | C | Flange DN100 |
N | 1½ NPT Thread | D | Flange DN150 | |
A | Flange DN50 | E | Flange DN200 | |
B | Flange DN80 | Y | Special Custom | |
Electronic Unit | 2 | (4〜20)mA 24V DC/HART Two-Wire | ||
3 | (4〜20)mA 220V AC/Four-Wire Dual Chamber Housing | |||
4 | RS485 MODBUS-RTU Communication Protocol /Four-Wire | |||
Y | Special Custom | |||
Cable Inlet | M | M20*1.5 | ||
N | 1/2 NPT | |||
Scene Display/ Programmed | A | LCD Without Backlight | ||
X | LCD With Backlight | |||
Range | 1 | 0-5 m | ||
2 | 0-10 m | |||
3 | 0-20 m | |||
Special Custom | Y | Special Custom |
7.Field case:
8.FAQ:
1. Question: How to choose the model of Radar level gauge?
A: Please contact our professional sales representatives or engineers, we will choose the best solution for you according to your site conditions.
2. Q: How about the quality of your products? How about warranty?
A: We have 20 years of experience in R&D and production. Our products are exported to more than 80 countries around the world, and are highly praised by users. Our product warranty is 18 months. If the product itself has quality problems, we will provide you with new equipment for free.
3. Q: Can I source samples? What is the MOQ?
A: Of course, we have sufficient stock to help you get samples in the shortest time, and our MOQ is 1PCS.
4. Q: What is your shipping method?
A: We have our own cooperating freight forwarder, which can ship by express door to door, air to airport, railway to station, sea to port, if you have your own freight forwarder, we can ship the goods to your designated China warehouse for free.
5. Q: What are the payment methods?
A: We support TT payment, credit card online payment, RMB payment, Western Union payment, LC payment.